Biomechanical Stiffness and Strength of New Versus Reused Stainless Steel Uniplanar Tibial External Fixator Constructs in a Low-Resource Setting

Main Article Content

Cris S. Dedumo, MD
Christopher C. Balaba, MD
Ma. Geneva S. Khu, MD

Abstract

Introduction. External fixation is used in the initial or definitive management of open fractures. Branded fixators are costly and often unavailable in low-resource countries. Low-cost locally available stainless steel fixators are relatively easy to procure.


When these low-cost fixators are depleted in hospitals and purchase cost is prohibitive for patients, the reuse of non-implanted components (the rods and clamps, referred to as outriggers) is a frequent alternative. New Schanz pins should be implanted into bone to reduce the risk of infection. The reuse of outriggers translates to significant savings both for hospitals and patients.


Knowing the stiffness and strength of reused versus new fixators will help guide their policies regarding reuse.
Objectives. The general objective of this study was to assess the biomechanical stiffness and strength of both new and previously
used external fixator constructs available in our hospital. Specifically, this study compared the axial stiffness, bending stiffness,
torsional stiffness, and ultimate strength of new versus previously used low-cost uniplanar tibial external fixator constructs. In
addition, this study compared the axial stiffness and ultimate strength of an all-new low-cost uniplanar tibial external fixator
constructs using five Schanz pins versus six Schanz pins.
Methodology. Forty-five plastic tibia were osteotomized at midshaft to create a fracture gap, simulating a comminuted diaphyseal fracture. Tibias were randomly divided into three groups of fifteen specimens. Each tibia was stabilized using five new Schanz pins in a uniplanar configuration held by one of three constructs: 1) with all-new components, 2) once-used and re-sterilized outriggers, or 3) twice-used and re-sterilized outriggers. Specimens were then biomechanically tested to determine fixation stiffness in axial
compression, bending, and torsion. Static loading until failure was also performed to determine ultimate construct strength.


A fourth group of five specimens (osteotomized tibias) were stabilized using all-new components with six Schanz pins (three pins in each fracture segment). These specimens were tested to determine axial stiffness and ultimate strength. Results were then compared to the first group (5-pin all-new components).
Results. There were no significant differences among the first three groups in terms of axial stiffness, axial strength, and bending stiffness. In the torsion test, the reused fixators were even stiffer than the all-new group.


The all-new fixators using six Schanz pins were significantly stiffer and stronger versus the all-new fixators using five Schanz pins.
Conclusion. Reused, locally available stainless steel uniplanar tibial external fixators were mechanically comparable to new fixators in terms of axial stiffness, bending stiffness, and ultimate strength. Reused fixators were superior in terms of torsional stiffness versus new fixators. The reuse of non-implantable fixator components is a viable option without compromising construct mechanical strength even if the components have undergone two cycles of clinical use and reprocessing.


The study also concludes that in using new external fixators, increasing the number of pins from five Schanz pins to six Schanz pins increased the construct’s axial stiffness two times and increased the construct’s axial strength four times.

Article Details

How to Cite
Dedumo, C., Balaba, C., & Khu, M. G. (2023). Biomechanical Stiffness and Strength of New Versus Reused Stainless Steel Uniplanar Tibial External Fixator Constructs in a Low-Resource Setting. Philippine Journal of Orthopaedics, 38(1), 25–35. https://doi.org/10.69472/poai.2023.05
Section
Original Articles
Author Biography

Christopher C. Balaba, MD, Northern Mindanao Medical Center, Capitol Compound, Cagayan de Oro City, Misamis Oriental, Philippines

 

 

References

Krah KL, Yao LB, Sery BJLN, et al. Epidemiological data of motorcycle accident at surgical emergency of Bouake teaching hospital. Rev Int Sc Med. 2013;15:61–64. https://revues-ufhb-ci.org/fichiers/FICHIR_ARTICLE_190.pdf

Mathieu L, Grosset A, Bertani A, et al. Type III open tibia fractures in low-resources setting. Part 1: strategy and principles of limb salvage. Med Sante Trop. 2018;28(2):133–9. https://pubmed.ncbi.nlm.nih.gov/29997068 https://doi.org/10.1684/mst.2018.0775

Versoza N, Miles R. Severity of road crashes involving pedestrians in Metro Manila, Philippines. Accid Anal Prev. 2016;94:216–26. https://pubmed.ncbi.nlm.nih.gov/27340839 https://doi.org/10.1016/j.aap.2016.06.006

Museru LM, Mcharo CN. The dilemma of fracture treatment in developing countries. Int Orthop. 2002;26(6):324–7. https://pubmed.ncbi.nlm.nih.gov/12466862 PMCID: PMC3620973 https://doi.org/10.1007/s00264-002-0408-7

Beck DJ, Seligson D. External fixator parts should not be reused. J Orthop Trauma. 2006;20(1):39–42. https://pubmed.ncbi.nlm.nih.gov/16424808 https://doi.org/10.1097/01.bot.0000189882.83045.a7

Bible, Jesse E, Hassan R Mir. External fixation: principles and applications. J Am AcadOrthop Surg. 2015;23(11):683–90. https://pubmed.ncbi.nlm.nih.gov/26306568 https://doi.org/10.5435/JAAOS-D-14-00281

. Ma C, Wu C, Jiang J, Tu Y, Lin T. Metaphyseal locking plate as an external fixator for open tibial fracture: clinical outcomes and biomechanical assessment. Injury. 2017;48(2): 501-5. https://pubmed.ncbi.nlm.nih.gov/27919511 https://doi.org/10.1016/j.injury.2016.11.031

. Qiu X, Yuan H, Zheng X, Wang J, Xiong J, Chen Y. Locking plate as a definitive external fixator for treating tibial fractures with compromised soft tissue envelop. Arch Orthop Trauma Surg. 2014;134(3):383–8. https://pubmed.ncbi.nlm.nih.gov/24362495 https://doi.org/10.1007/s00402-013-1916-1

. Thamyongkit S, Bachabi M, ThompsonJM, Shafiq B, Hasenboehler EA. Use of reprocessed external fixators in orthopaedic surgery: a survey of 243 orthopaedic trauma surgeons. Patient Saf Surg. 2018;12:10. https://pubmed.ncbi.nlm.nih.gov/29930708 https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5991444 https://doi.org/10.1186/s13037-018-0156-2

Mahapatra S, Rengarajan N. Use of recycled external fixators in management of compound injuries. Expert Rev Med Devices. 2017;14(1):83-5. https://pubmed.ncbi.nlm.nih.gov/27929693 https://doi.org/10.1080/17434440.2017.1265886

Goh J, Thambyah A, Noor Ghani A, Bose K. Evaluation of a simple and low-cost external fixator. Injury. 1997;28(1):29–34. https://pubmed.ncbi.nlm.nih.gov/ 9196623 https://doi.org/10.1016/s0020-1383(96)00149-0

Noor MA. A simple and inexpensive external fixator. Injury. 1988;19(6): 377–8. https://pubmed.ncbi.nlm.nih.gov/3267638 https://doi.org/10.1016/0020-1383(88)90126-x

Oni OO, Capper M, Soutis C. A finite element analysis of the effect of pin distribution on the rigidity of a unilateral external fixation system. Injury. 1993;24(8):525–7. https://pubmed.ncbi.nlm.nih.gov/8244544 https://doi.org/10.1016/0020-1383(93)90028-5

Shahid M, Malik S. A review of the biomechanical role of a unilateral external fixator in the fracture repair process. 2016. Corpus ID: 212446276

Sellei RM, Kobbe P, Dadgar A, Pfeifer R, Behrens M, von Oldenburg G, et al. External fixation design evolution enhances biomechanical frame performance. Injury. 2015;46(Suppl 3):S23–6. https://pubmed.ncbi.nlm.nih.gov/26458295 https://doi.org/10.1016/S0020-1383(15)30007-3

Cinthuja P, Wijesinghe PCI, Silva P. Use of external fixators in developing countries: a short socioeconomic analysis. Cost Eff Resour Alloc. 2022;20(1):14. https://pubmed.ncbi.nlm.nih.gov/35351146 https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8961085 https://doi.org/10.1186/s12962-022-00353-4

Guideline for disinfection and sterilization in healthcare facilities. Infection Control. Centers for Disease Control and Prevention. U.S. Department of Health and Human Services. 2008. https://www.cdc.gov/infectioncontrol/guidelines/disinfection/index.html

Mohapatra S. Sterilization and disinfection. Essentials of Neuroanesthesia. 2017:929–44. https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7158362 https://doi.org/10.1016/B978-0-12-805299-0.00059-2

Dirschl DR, Smith IJ. Reuse of external skeletal fixator components: effects on costs and complications. J Trauma. 1998;44(5):855–8. https://pubmed.ncbi.nlm.nih.gov/9603088 https://doi.org/10.1097/00005373-199805000-00018

Dirschl DR. Reuse of selected external fixator components is safe and should be supported. J Orthop Trauma. 2006;20(1):43–6. https://pubmed.ncbi.nlm.nih.gov/16424809 https://doi.org/10.1097/01.bot.0000189883.21163.40

Sung JK, Levin R, Siegel J, Einhorn TA, Creevy WR, Tornetta P 3rd. Reuse of external fixation components: a randomized trial. J Orthop Trauma. 2008;22(2):126–30. https://pubmed.ncbi.nlm.nih.gov/18349781 https://doi.org/10.1097/BOT.0b013e318162e55c

Horwitz DS, Schabel KL, Higgins TF. The economic impact of reprocessing external fixation components. J Bone Joint Surg Am. 2007;89(10):2132–6. https://pubmed.ncbi.nlm.nih.gov/17908887 https://doi.org/10.2106/JBJS.F.01409

Matsuura M, Lounici S, Inoue N, Walulik S, Chao EY. Assessment of external fixator reusability using load- and cycle-dependent tests. Clin Orthop Relat Res. 2003;(406): 275–81. https://pubmed.ncbi.nlm.nih.gov/12579028 https://doi.org/10.1097/01.blo.0000037443.23683.7c

Tapscott, David C. and Wottowa, Christopher. Orthopedic implant materials. In: StatPearls [Internet]. Treasure Island (FL): StatPearls Publishing; 2023 Jan.

Jul 25. https://pubmed.ncbi.nlm.nih.gov/32809340 Bookshelf ID: NBK560505

ASTM F1541-17. Standard specification and test methods for external fixation devices. American Society for Testing and Materials. West Conshohocken, PA. 2017. https://standards.iteh.ai/catalog/standards/astm/d737b6ed-d0ea-4ede-9f94-965aae8002f9/astm-f1541-1726.

Briggs BT, Chao EY. The mechanical performance of the standard Hoffmann-Vidal external fixation apparatus. J Bone Joint Surg Am. 1982;64(4): 566–73. https://pubmed.ncbi.nlm.nih.gov/7068699.

Shi D, Liu K, Zhang H, Wang X, Li G, Zheng L. Investigating the biomechanical function of the plate-type external fixator in the treatment of tibial fractures: a biomechanical study. BMC Musculoskelet Disord. 2020;21(1):128. https://pubmed.ncbi.nlm.nih.gov/32106851 https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7047408 https://doi.org/10.1186/s12891-020-3144-5

Bottlang M, Doornink J, Fitzpatrick DC, Madey SM. Far cortical locking can reduce stiffness of locked plating constructs while retaining construct strength. J Bone Joint Surg Am. 2009;91(8):1985–94. https://pubmed.ncbi.nlm.nih.gov/19651958 https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2714811 https://doi.org/10.2106/JBJS.H.01038

Epari DR, Kassi JP, Schell H, Duda GN. Timely fracture-healing requires optimization of axial fixation stability. J Bone Joint Surg Am. 2007;89(7):1575–85. https://pubmed.ncbi.nlm.nih.gov/17606797 https://doi.org/10.2106/JBJS.F.00247

Button G, Wolinsky P, Hak D. Failure of less invasive stabilization system plates in the distal femur: a report of four cases. J Orthop Trauma. 2004;18(8):565–70. https://pubmed.ncbi.nlm.nih.gov/15475855 https://doi.org/10.1097/00005131-200409000-00015

Sommer C, Gautier E, Müller M, Helfet DL, Wagner M. First clinical results of the Locking Compression Plate (LCP). Injury. 2003;34(Suppl 2):B43–54. https://pubmed.ncbi.nlm.nih.gov/14580985 https://doi.org/10.1016/j.injury.2003.09.024

Zderic I, Oh J, Stoffel K, Sommer C, Helfen T, Camino G, et al. Biomechanical analysis of the proximal femoral locking compression plate: do quality of reduction and screw orientation influence construct stability? J Orthop Trauma. 2018 Feb;32(2): 67–74. https://doi.org/10.1097/BOT.0000000000001008.

Ang BFH, Chen JY, Yew AKS, et al. Externalised locking compression plate as an alternative to the unilateral external fixator: a biomechanical comparative study of axial and torsional stiffness. Bone Joint Res. 2017;6(4):216–23. https://pubmed.ncbi.nlm.nih.gov/28420623 https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5415900 https://doi.org/10.1302/2046-3758.64.2000470

Kouassi KJ, Cartiaux O, Fonkoué L, Detrembleur C, Cornu O. Biomechanical study of a low-cost external fixator for diaphyseal fractures of long bones. J Orthop Surg Res. 2020;15(1):247. https://pubmed.ncbi.nlm.nih.gov/32631381 https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7339426 https://doi.org/10.1186/s13018-020-01777-5

Pomares JC, Pereiro-Barceló J, González A, Aguilar R. Safety issues in buckling of steel structures by improving accuracy of historical methods. Int J Environ Res Public Health. 2021;18(22): 12253. https://pubmed.ncbi.nlm.nih.gov/34832006 https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8618944 https://doi.org/10.3390/ijerph182212253